11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax (727) 442-5699 • [email protected]
F-2600 & F-2700 Vortex Flow Meter Manual 02/15 - 0808-7 / 19204 Page 104
5.3 TROUBLESHOOTING THE FLOW METER
5.4 FIRST CHECK ITEMS:
Installation Direction Correct
Installation Depth Correct (Insertion style meter)
Power and Wiring Correct
Application Fluid Correct
Meter Range Correct for the Application
Meter Conguration Correct
Describe Installation Geometry; i.e. upstream diameters, valve position,
downstream diameters, etc.
5.5 RECORD VALUES:
Record the following values from the Run Menu with the meter installed in order to
determine the operating state of the ow meter:
With Flow With No Flow (if possible)
Flow =
Temperature=
Pressure =
Density =
Error Messages? =
Record the following values from the Hidden Diagnostics Menu with the meter
installed: (Use password 16363 to access.)
With Flow With No Flow (if possible)
f =
 =
A =
A1 =
A2 =
A3 =
A4 =
V =
RTD1 =
RTD2 =
!
WARNING
Before attempting any ow meter repair, verify that the line is not pressurized. Always remove
main power before disassembling any part of the mass ow meter. Use hazardous area precautions
if applicable. Static sensitive electronics - use electro-static discharge precautions.